Ngày đăng: 26/06/2022
Mã sản phẩm: PW-SP-F
Giá tham khảo: 1,000 USD
Xuất xứ: Trung Quốc
Bảo hành: 12 months
Phương thức thanh toán: transfer
Khả năng cung cấp: 200 PCS per month
Đóng gói: yes
Liên hệFixed Sampling Probe
Features
☆ With large diameter SMC pneumatic valve, the sample gas circuit is smooth and not easy to be blocked
☆ With backflush solenoid valve and sampling solenoid valve, no need extra valve in the CEMS cabinet
☆ Two-stage filtration, cleaner flue gas
☆ High temperature heating function, no loss of flue gas components
☆ Sampling probe with explosion-proof function optional, standard ⅡC T3
Model |
PW-SP-F series |
Sampling temprature |
<600°C |
Working temprature |
-20~80℃ |
Sampling chamber heating temperature ( second filtration) |
Maximum continuous heating temperature 150°C; alarm when < 130°C |
Filter element |
Silicon carbide material, 2pm , L=75mm (stainless steel filter optional ) |
Filter chamber capacity |
40cm³ |
Backblow compressor air pressure |
0.3~0.8MPa |
Backblow connection |
OD6/4mm、OD8/6mm (optional) |
Sampling outlet |
OD6/4mm、OD8/6mm (optional) |
Calibration gas inlet |
OD6/4mm stainless steel |
Power supply |
220V AC 50Hz 400W ( other power optional) |
Solenoid valve voltage |
24V |
Principle
After the primary filter on the probe rod, the flue gas enters the sampling chamber for secondary precision filtration, then enters the heat tracing pipeline through the sampling stop valve, and finally is sent to the analyzer