NOx/O2 Analyzer
Features
☆ Free from the interference of SO2,CO2 and moisture
☆ Can use no water removal unit, less maintenance and more convenient
☆ Imported double pool thick film zirconia sensor, can measure NOX and O2 at the same time.
☆ With remote data transmission function
☆ With data storage function, export data by USB disk or SD card
☆ With backblow & calibration signal points, easy for integration
☆ Isolated analog signal output, can choose 4-20mA,0-20mA or 0-1V,0-5V.
Model |
PW-NA series |
Sensor |
Nano ceramic double cell thick film sensor |
NOx measuring range |
0-1000ppm |
O2 measuring range |
0-25% |
Stability |
±1%FS/7D |
T90 response time |
≤10S |
Control cabinet installation |
Wall mounted, In-site mounted(optional) |
Sampling probe |
Insert into flue straightly |
Calibration mode |
Zero air/standard air - two /three /multi point |