Dilution Gas Sampling Probe
Features
☆ More stable dilution ratio,better consistency
☆ Reduce the water content in the sample gas, co-mpletely eliminate the measurement influence of condensed water
☆ After remove dust & NH3, sample gas complete-
ly meets the requirements of the analyzer
☆ No need heating line
☆ Sample gas transmission fast, less maintenance & consumables
☆ Double filtration( sampling probe cavity and sonic hole ), filtration level 0.1µm, effectively prevent sonic hole clogging
☆ Backblow function, suitable for high dust, high pollution conditions
☆ Escape NH3 removal rate is above 99%
☆ Standard dilution ratio: 1:100 (other ratios are optional)
Model No. |
PW-SP-D series |
Dilution air flow rate |
6.5-7.5 LPM,50 Psig minimun |
Diluted air purity |
-40℃ <1ppb CO,CO2,NOx, SO2 |
Vacuum port |
-15" Hg |
Sonic orifice |
Duran glass |
Absolute pressure of flue gas range |
-10kpa~10kpa |
Backblow frequency |
outer control |
Backflow time |
outer control |
Fast recycle ejector |
choose according to the specific situation |
Pressure for compressed air |
0.4~0.7Mpa |
Heat power |
450W |
Preheating time |
2H |
Control thermocouple |
Mechanical temperature controller |